Shenzhen Yierp Technology Co., Ltd.
+8619556531621
Dc Inverter Ground Water Source Heat Pump

Dc Inverter Ground Water Source Heat Pump

The method of heat transfer is more in line with human thermal perception. When a local geothermal heat pump is paired with low-temperature hot water floor heating, the supply water temperature only needs to be 40–45°C. Heat is evenly released through the floor by radiation, forming an indoor gradient distribution of “floor temperature 25–28°C, head temperature 20–22°C,” perfectly matching the human comfort requirement of “warm feet, cool head.”

Send Inquiry
    • Description
    • Specification

    Ground source heat pumps achieve highly efficient heat exchange between water and water, providing energy savings, stability, environmental friendliness, and comfort. They are also multi-functional, capable of providing heating, cooling, and domestic hot water, reducing unnecessary costs. Ground source heat pumps offer flexible installation and wide application, allowing for selection of three installation methods-buried pipe type, groundwater type, and surface water type-depending on site conditions, geological environment, and water resources.

    Buried pipe ground source heat pump

    Ground source heat pumps use PE heat exchange pipes to exchange heat with the underground soil, eliminating the need to extract water from underground sources and minimizing environmental impact. During construction, the PE pipes are arranged in a serpentine pattern, making operation simple and cost-effective, suitable for scenarios requiring ample space.

     

    Groundwater source heat pump

    Groundwater is used as the heat exchange medium. Groundwater is extracted through wells, exchanged through the main unit, and then all the groundwater is reinjected back underground to achieve heat transfer. This method has a higher heat exchange efficiency than buried pipe systems. This approach requires abundant groundwater resources and a stable groundwater level in the installation area.

     

    Surface water ground source heat pump

    By directly immersing the heat exchange coils in surface water, heat exchange occurs between the surface water and the heat exchange medium within the coils. This method is simple to construct and has the lowest cost. It is suitable for areas with stable surface water supply, requiring sufficient water volume, minimal temperature fluctuations throughout the year (no freezing or thin ice formation in winter), and water quality that meets heat exchange requirements. Ground source heat pumps combine multiple advantages such as energy saving, stability, comfort, environmental protection, economy, and safety. They not only meet users' needs for a constant and comfortable environment but also align with the national green development strategy, making them the optimal choice for modern building energy supply with broad application prospects and long-term social, economic, and environmental benefits.

    44

     

     

    Hot Tags: dc inverter ground water source heat pump, China dc inverter ground water source heat pump manufacturers, suppliers, factory, Dc Inverter Ground Water Source Heat Pump, Heat Pump HVAC System, ground source heat pump water heater, Water To Water Heat Pump, water to water geothermal heat pump, R32 Dc Inverter Water Source Heat Pump

    Next: No Information